• Home
  • About
  • Policies
  • Contact
    • Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
Advanced Search
View Item 
  •   Home
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği / Civil Engineering
  • Bildiriler, Kongreler ve Sempozyumlar / Declarations, Congresses and Symposiums
  • View Item
  •   Home
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği / Civil Engineering
  • Bildiriler, Kongreler ve Sempozyumlar / Declarations, Congresses and Symposiums
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Increasing Seismic Capacity of Existing Reinforced Concrete Buildings by the Use of FRP and Steel Fuse Elements

Thumbnail
View/Open
Increasing Seismic Capacity of Existing Reinforced Concrete Buildings by the Use of FRP and Steel Fuse Elements.pdf (603.6Kb)
Author
Türk, Ahmet Murat
Cömert, Mustafa
Coşgun, Cumhur
Kesti, M. Gökhan
Type
conferenceObject
Date
2010
Language
en_US
Metadata
Show full item record
Abstract
Two of major problems for seismic rehabilitation of existing buildings are the necessity of evacuation of the occupants from the basis of the construction works and the limited time frame available for the actual construction site works. All of these problems often cause delays and cost overruns in the seismic rehabilitation projects. One possible way to eliminate these problems to a great extent is the use of FRP (fiber reinforced polymer) and steel fuse elements to improve seismic capacity. There is a huge stock of seismically deficient buildings that needs to be upgraded immediately according to the current Turkish Seismic Code (TSC 2007). The main aim of the paper is the examination of the possibility of using FRP and steel fuse elements on existing frame elements for seismic upgrading of the school and hospital buildings in Turkey. To investigate the possibility and effectiveness of the use of the hybrid system, a comparative study was performed. The comparison has made between typical framed RC building and the same building after retrofitting with FRP confinement and steel fuse elements around joints. By using nonlinear static (pushover) analysis, the performance levels of structural members were evaluated for both structures. This method seems as viable solution for the buildings considered in terms of safety and time.
Subject
Reinforced concrete
Seismic rehabilitaiton
Retrofit
Cfrp
Steel fuse
URI
https://hdl.handle.net/11413/4042
Collections
  • Bildiriler, Kongreler ve Sempozyumlar / Declarations, Congresses and Symposiums [55]
  • Scopus Publications [724]

İstanbul Kültür University

Hakkında |Politika | Kütüphane | İletişim | Send Feedback | Admin

Istanbul Kültür University, Ataköy Campus E5 Karayolu Üzeri Bakırköy 34158, İstanbul / TURKEY
Copyright © İstanbul Kültür University

Creative Commons Lisansı
IKU Institutional Repository, Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

Designed by  UNIREPOS

İKU Kütüphane


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageBy PublisherRightsPubmedScopusWoSThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageBy PublisherRightsPubmedScopusWoS

My Account

Login

İstanbul Kültür University

Hakkında |Politika | Kütüphane | İletişim | Send Feedback | Admin

Istanbul Kültür University, Ataköy Campus E5 Karayolu Üzeri Bakırköy 34158, İstanbul / TURKEY
Copyright © İstanbul Kültür University

Creative Commons Lisansı
IKU Institutional Repository, Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

Designed by  UNIREPOS